Oracle Error RMAN-06755: WARNING: datafile string: incremental-start SCN is too recent; using checkpoint SCN string instead

Oracle Error Message

RMAN-06755: WARNING: datafile string: incremental-start SCN is too recent; using checkpoint SCN string instead

Reason for the Error

The incremental-start sysetm change number (SCN) which was specified when starting an incremental datafile backup is greater than the datafile checkpoint SCN, which could cause some blocks to be missed.

Solution

Specify a smaller incremental-start system change number (SCN).

Share:

Leave A Reply

Your email address will not be published. Required fields are marked *

You May Also Like

Oracle Error Message ORA-24328: illegal attribute value Reason for the Error The attribute value passed in is illegal. Solution Consult...
Oracle Error Message ORA-01346: LogMiner processed redo beyond specified reset log scn Reason for the Error LogMiner has detected a...
Oracle Error Message ORA-13241: specified dimensionality does not match that of the data Reason for the Error An error occurred...