Oracle Error ORA-16277: specified table is not supported by logical standby database

Oracle Error Message

ORA-16277: specified table is not supported by logical standby database

Reason for the Error

A call was made to DBMS_LOGSTDBY.INSTANTIATE_TABLE to instantiate an unsupported table on the logical standby database. Tables with unsupported data types cannot be replicated to a logical standby database.

Solution

Specify a table which is not listed in the DBA_LOGSTDBY_UNSUPPORTED_TABLE view.