HPE NonStop SQL/MX Error – 1154 Cannot create object object-name as the table size is too big to fit on the system.

In this blog post, let’s learn about the error message “1154 Cannot create object object-name as the table size is too big to fit on the system.” when working with HPE NonStop SQL/MX, the reason for the error and the solution to fix this error message.

Error Message

1154 Cannot create object object-name as the table size is too big to fit on the system.

Reason for the Error

NonStop SQL/MX could not create the object because the requested table size is bigger than the total amount of disk space available on the cluster.

Solution

Check that the table size requested fits the cluster, and then retry the statement

Leave A Reply